Sensors, Instrumentation,Equipment and Suppliesfor Analytical BioprocessApplications®BioProcess TechnologiespH | Dissolved Oxygen2014Bioprocess
10What’s the difference between the 3 cap styles?odes pH Electrodes pH Electrodes pH Electrodes pH Electrodes pHStandard S8 Metric CapThis FermProbe®s
11H Electrodes pH Electrodes pH Electrodes pH Electrodes pH ElectF-615 pH FermProbeF-635 pH FermProbeF-695 pH FermProbeT-Pull®cap styleStandard S8 Met
12T-Pull®pH FermProbe®— Style 1ModelF-615pH FermProbewith T-Pull capThe T-Pull style FermProbe pH electrodes are designed tobe used in bioprocess appl
13How to Order an Electrode(1) Choose Electrode Model.If the electrode needs to fit an existing cable, check the cable con-nector and note its color.
14pH FermProbe®with S8 Metric Cap — Style 2225 mmlength325 mmlength200 mmlengthCLASSFCLASSGCLASSHModelF-635pH FermProbewith S8 capodes pH Electrodes p
15o r d e r i n g i n f o r m a t i o nElectrode UseWithThese Electrode ElectrodeModel Class Housing Models Length Part NumberModel F-635 pH FermProbe
16pH FermProbe with K9 Metric Cap — Style 3odes pH Electrodes pH Electrodes pH Electrodes pH Electrodes pHThe FermProbe pH electrode is available with
17How to Order an Electrode(1) Choose Electrode Model.If the electrode needs to fit an existing cable, check the cable con-nector and note its color.
181.0"25 mm1.4"36 mmHow to Choose a Housing Style:Indentifying the Vessel Port Style1.0"25 mm2.3"58 mmSTANDARD 25 mm SIDE PORTFoun
19T-Pull® styleFermProbe®Model 330Model 320T-Pull® styleFermProbe®Model 336Model 326pH electrodes and housingsavailable for this port.Cutaway of vesse
2atalog The BioProcess Technologies®Catalog The BioProcess TechnoVisit Our WebsitePlease visit our websiteNeed more information aboutproducts in ourca
201.4"35.5 mm0.9"23 mmHow to Choose a Housing Style:Additional Sanitary InstallationsNOVASEPTIC SANITARY SIDE PORTSometimes found on vessels
21Model 367T-Pull® styleFermProbe®Cutaway of vessel wall withhousing and pH electrodeinstalledousings pH Housings pH Housings pH Housings pH Housings
23usings pH Housings pH Housings pH Housings pH Housings pH1. Do I want a Guarded or Unguarded Housing?The electrode/housing assembly can accidentally
24Additional Features Include:• Guarded versions for rugged handling while protecting the pH glass bulbin a production environment.• Unguarded version
25CLASSAo r d e r i n g i n f o r m a t i o nHow to Order a HousingModel 320 Insertion LengthsModel 330 Insertion Lengths(1)Confirm that the vessel ha
26Additional Features Include:• Guarded versions for rugged handling while protecting the pH glass bulb.in a production environment.• Unguarded versio
27How to Order a Housing(1)Confirm that the vessel has a B. Braun Biotech 25 mm side port. Cutawayviews and dimensions are shown on pages 18 and 19.(2
28Housings with Sanitary Flangeso r d e r i n g i n f o r m a t i o nCLASSACLASSAHousings for SanitaryTees and Novasaptic Side PortsModel 357Unguarded
29usings pH Housings pH Housings pH Housings pH Housings pH HExploded and Inserted ViewsModel 367GuardedHousingInstalled in a11/2”TeeCutaway ofvessel
29usings pH Housings pH Housings pH Housings pH Housings pH HExploded and Inserted ViewsModel 367GuardedHousingInstalled in a11/2”TeeCutaway ofvessel
3nologies®Catalog The BioProcess Technologies®Catalog The BioBroadley-James Corporation19 Thomas, Irvine, CA 92618 USAwww.broadleyjames.comFermProbe
30Metric Housings for Standard 25 mm Side PortsThese housings are designed to be used with models F-635 and F-695Metric FermProbe®electrodes and model
31(1) Confirm that the opening is a stand ard 25 mm side port. Cutawayviews and dimensions are shown on pages 18 and 19.(2) Determine whet her the app
Redox FermProbes®Fits all suitable FermProbe housingsWorks with standard FermProbe cablesCompatible with pH transmitters that have a millivoltdisplay
33How to Order aRedox Electrode(1) Choose Electrode Model.If the electrode needs to fit an existing cab le, check the cable con-nector and note its co
Steam Sterilizable and AutoclavableOxyProbe®D.O. Sensorssors Dissolved Oxygen Sensors Dissolved Oxygen Sensors Dissolv34Original T-Pull®HandleDevelope
ved Oxygen Sensors Dissolved Oxygen Sensors Dissolved Oxygen35Easy to Replace Membrane BodyThe outer silicone layer protects the innerteflon layer, an
36OxyProbe®D.O. Sensorsfor Standard 25 mm Side PortsModel D400 OxyProbe®D.O. Sensor SeriesThe OxyProbe®D400 series dissolved oxygen sensor offers the
37What makes OxyProbe®sensors unique?The internal seals of an OxyProbe are all mechanical seals using o-rings. There areno adhesives to leak or fail i
38OxyProbe®D.O. Sensors for B. Braun Biotech25 mm Safety Side PortsModel D430 Series OxyProbe®D.O. SensorsThe ports of B. Braun Biotech fermentation v
39How to choose a sensor:(1)Confirm that the vessel has a 25 mm B. Braun Biotechside port, as in the drawin g above.(2)Deter mine how far the sensor s
FermProbe®pH ElectrodesSteam Sterilizable and Autoclavabletrodes pH Electrodes pH Electrodes pH Electrodes pH Electrodes pBroadley-James Corporation (
40nsors Dissolved Oxygen Sensors Dissolved Oxygen Sensors DissoBENEFITS:• Full zero and air test to verify the dissolved oxygen sensor is fit for pu
41Model D200 SeriesThe OxyProbe®19 mm dissolved oxygen sensor features the same rugged andversatile design as the 25 mm OxyProbe. Although the 19 mm O
41Model D200 SeriesThe OxyProbe®19 mm dissolved oxygen sensor features the same rugged andversatile design as the 25 mm OxyProbe. Although the 19 mm O
42OxyProbe®D.O. Sensor with 1.5”Sanitary Flangefor Sanitary Pipe Tee and Novaseptic Side PortsModel D 210 Series OxyProbe®D.O. Senso rsThese sensors a
43olved Oxygen Sensors Dissolved Oxygen Sensors Dissolved OxygeStandard Mounting forModel D210 Series D.O. SensorsThe Models D210 Series D.O. OxyProbe
44o r d e r i n g i n f o r m a t i o nSensor Sensor Typical SensorModel Length Insertion Length Part NumberD140 Series 12 mm OxyProbe with Straight C
45Typically a benchtop application is less than 5 L, and uses aglass vessel or flask. Usually the entire vessel can be placed orwheeled into an autocl
46ance Maintenance Maintenance Maintenance Maintenance MaintMaintenanceService and SuppliesBroadley-James Corporation (U.S. & Canada) Toll-Free: 8
47tenance Maintenance Maintenance Maintenance Maintenance MBroadley-James®Maintenance Supplies,Designed to make your job easier.The primary components
Complete Rebuild Servicefor 25 mm, 19 mm and 12 mm D.O. SensorsBroadley-James provides complete D.O. sensor rebuildservice.This service includes rebui
pH Electrodes pH Electrodes pH Electrodes pH Electrodes pH Elec5New and Improved pH Glass BulbThe Broadley-James cobalt blue pH bulboffers the optimum
It is much easier to replace o-ring seals rather than sealant. Withsealant, it is necessary to eliminate all residue before re-applyinganother seal. A
50Cathode Assembly for 25 mm and 19 mm SensorsThis part number includes the cathode assembly and both o-rings requiredto seal it into the sensor body.
51Connectorsfor 25 mm, 19 mm and 12 mm D.O. Sensors4-Pin Straight ConnectorStraight 4-Pin ConnectorPart Number DescriptionAM-9202 25 mm SensorAM-9203
52Membrane Cartridges for25 mm and 19 mm D.O. SensorsSingle Cartridge KitThis kit includes everything required to replacethe membrane cartridge and in
53Membrane Cartridges for12 mm D.O. SensorsSingle Cartridge KitThis kit includes everything required toreplace the membrane cartr idge and internalo-r
54O-rings for D.O. SensorsPart Number Description QuantityAG-9206-10 4 internal o-rings, 1 gasket 10 setsInternal O-rings for 19 mm and 25 mm D.O. Sen
55D405OxyProbe®O-rings for D.O. SensorsPart Number QuantityAG-S016-50 50AG-S016-25 25AG-S016-10 1019 mm External O-ringsThis silicone o -ring will fit
56O-rings for D.O. Sensors and pH ElectrodesPart Number Compatible Probes Quantity300-P101 F-600, F-607 and F-615 FermProbes 3 sets300-P102 F-695 and
57O-rings for 25mm HousingsStandard 25 mm Housing O-ringsBroadley-James Models 320, 330, 370 housings use the same set of o-rings.O-rings should be in
Accessories58ories Accessories Accessories Accessories Accessories AccessoriLine-Powered Four-StationD.O. Sensor PolarizerpH & D.O. Sensor Simulat
330F-615 pH FermProbeF-607 pH FermProbeF-600 pH FermProbeHousings forstandard 25mmside ports320336326370Housings forB. Braun Biotech 25 mmside portsHo
The primar y components of a measurement loop are the sensors and transmitters. However, whenreadings are suspect or if noise and interference are a p
60ories Accessories Accessories Accessories Accessories AccessorStorage ContainersThese strong storage containers were designed for industrial applica
61ries Accessories Accessories Accessories Accessories AccessorieCable AdapterThis cable adapter converts any pH cable with an AK9 connectorto a stand
62ories Accessories Accessories Accessories Accessories AccessoriRetainer Ring for 25 mm PortAll port retainer rings from Broadley-James Corporation a
63ies Accessories Accessories Accessories Accessories AccessorieD.O. Electrolyte SolutionIn critical biotech applications, the electrolyte should be c
64Ports and PlugsPart Number DescriptionAF-305-62-L055 Straight plugFor use with 25 mm B. BraunBiotech portsB. BraunBiotechPlugModel Part Number Dista
65ies Accessories Accessories Accessories Accessories AccessorieChamfered 25 mm Threaded PortPart Number DescriptionAF-110-60-L040 Standard threaded p
66ories Electronic Accessories Electronic Accessories Electronic AccCalibration Accessories for All D.O. SensorsD.O. Signal SimulatorThe simulator iso
67cessories Electronic Accessories Electronic Accessories Electrono r d e r i n g i n f o r m a t i o nPart Number DescriptionAM-9504 pH & D.O. Se
68ables Cables Cables Cables Cables Cables Cables Cables Cables CCablesBroadley-James Corporation (U.S. & Canada) Toll-Free: 800-288-2833 E-mail:
F-635 FermProbewith S8 cap325Metric Housingsfor 25 mmside ports335Side MountSee page 14B. Braun BiotechSee page 26F-695 FermProbewith K9 capSee page 1
Improved Stainless Steel pH ConnectorsBroadley-James offers both types of industry standard connectors, the “S8”and the“K9”, which havebeen used for d
70Cable Part Number Connector A Cable Type Cable Length Connector BCable Part Number Connector A Cable Type Cable Length Connector BCable Type:Type A
71Cable Part Number Connector A Cable Type Cable Length Connector BCable Part Number Connector A Cable Type Cable Length Connector BAX-1000-H5-N03FF H
72Cable Part Number Connector A Cable Type Cable Length Connector BCable Part Number Connector A Cable Type Cable Length Connector BCable Type:Type M
73Cable Part Number Connector A Cable Type Cable Length Connector BCable Part Number Connector A Cable Type Cable Length Connector BAX-1000-K5-N03FF K
74Cable Part Number Connector A Cable Type Cable Length Connector BCable Assemblies for Dissolved Oxygen SensorsCable Part Number Connector A Cable Ty
75Cable Part Number Connector A Cable Type Cable Length Connector BAX-5000-D4-D03L6 D4 D 3 ft (1 m) Lemo 6AX-5000-D4-D06L6 D4 D 6 ft (2 m) Lemo 6AX-50
CMYCMMYCYCMYK76-advert.pdf 1 8/29/14 2:55 PM
77ort Support Support Support Support Support Support Support SIf you don’t see what you’re looking forin this catalog …We have Over 2000 ItemsBroadle
M3 Bioreactor Control SystemDesigned for Cell Culture Or Microbial ApplicationsBuilt-In Continuous Historian To Securely Archive All Process DataVario
8How to Select a FermProbe®pH ElectrodeModel F-615 pH FermProbeModel F-635 pH FermProbeF-615 pH electrode with T-Pull capF-635 pH electrode with S8 me
Bioreactors®Suitable for Cell Culture & Microbial ApplicationsLike-for-Like Replace-ment of the OtherLeading ManufacturerSingle-Walled & Jacke
BioProcessTechnologiesCatalog of SuppliespH ElectrodesDissolved OxygenSensorsRedox ElectrodesStainless SteelHousingsSensor RebuildServiceCable Assembl
9o r d e r i n g i n f o r m a t i o no r d e r i n g i n f o r m a t i o nHousings and FermProbe®pH electrodes are offered in a varietyof lengths. Th
Komentáře k této Příručce