AL-1551 SIMULATION, TROUBLE CODES 10-8
43 01 Fusing temperature setup (Normal copy)
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
04 Fusing temperature setup 2
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
05 Duplex mode fusing temperature setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number corresponding to the duplex and press the START key. The setting is changed accordingly.
*The above shift temperature set by this simulation is added to the fusing temperature of single copy.
Main
code
Sub
code
Content
Code number Set temperature (°C)
0 175
1 180
2 185
3 190
4 195 (* Default)
5 200
Code number Set temperature (°C)
0 155
1 160
2 165
3 170 (* Default)
4 175
5 180
Code number Shift temperature (°C)
0°C
1-8°C
2-6°C
3-4°C
4-2°C
0°C
6+2°C
7+4°C
8+6°C
9+8°C
Zobrazit stránku 81