Regarding the Lamp (cont.)
Removing and Install-
ing the Lamp Unit
Info
• Be sure to remove the lamp unit by the
handle. Be sure not to touch the glass
surface of the lamp unit or the inside of
the projector.
• To avoid injury to yourself and damage
to the lamp, be sure to carefully follow
the steps below.
• Do not loosen other screws except for the
lamp unit cover and lamp unit.
• Please refer to the installation manual
included with the lamp unit.
1 Press on the projector to
turn off the power.
• Wait until the cooling fan stops.
Warning!
• Do not remove the lamp unit from the
projector right after use. The lamp will
be very hot and may cause burn or
injury.
2 Disconnect the power cord.
• Unplug the power cord from the AC
socket.
• Retract the antenna.
• Leave the lamp until it has fully cooled
down (about 1 hour).
3 Remove the lamp unit cover.
• Turn over the projector, and loosen the
user service screw that secures the
lamp unit cover. Then slide the cover
in the direction of the arrow.
Lamp
unit
BQC-PGM20X//1
AC socket
User service screw