16 - 17 ADF
(14)
Aligning sensor OFF to timing sensor OFF
The feed motor stops at the point when the timing sensor turns OFF. When the 2nd original onwards
is being fed, exit of exposed originals is carried out at the same time, and the original being fed must
be made to stand by before the reversal section until exit is completed. For this reason, the number of
drive pulses up to feed motor stop is set at the point when the timing sensor turns OFF to stop the
original being fed before the reversal section.
(15)
Timing sensor OFF to pause of forward rotation transport
After the timing sensor turns OFF, the original is transport for a specified number of pulses, and the
feed motor stops at the point when the original being fed arrives at the specified position before the
reversal section. The original stands by until exit of the output original is completed. The number of
drive pulses up to start of exit deceleration is set at the point when the turn guide sensor turns ON by
the leading edge of the output original, deceleration of the reversal motor is started at the point when
the timer has counted the number of pulses, and the original is output at low speed.
(16)
Completion of exit
At the point when the original is completely output onto the exit tray, the reversal motor stops, and exit
is completed.