Security Management Service, Product Price List
Part Numbe
r
Product Descri
p
tion Reference Price
276B-1120 Pull Station, Noncoded, Double Action, Break Glass, Plastic, Single
Pole, Open Curcuit, Screw Terminals, Key Reset
Fire 64.54
276B-RSB Pull Station Accessory, Surface Mt., Mounting Box, 278/FX-278 Lexan
Series
Fire 26.14
276-GLR Pull Station Accessory, Glass Replacement Rods for 278/FX-278
Lexan Series, 20 Count
Fire 33.34
276-K1 Reset Key & Tag for 'Key-Reset' Manual Stations Fire 17.86
277B-1110 Pull Station, Noncoded, Double Action, Break Glass, Plastic, Single
Pole, Open Curcuit, Wire Leads
Fire 45.86
278B-1110 Pull Station, Noncoded, Double Action, Break Glass, Plastic, Single
Pole, Open Curcuit, Screw Terminals, Wire Leads
Fire 44.00
278B-1120 Pull Station, Noncoded, Double Action, Break Glass, Plastic, Single Fire 80.54
278B-1420 Pull Station, Noncoded, Double Action, Break Glass, Plastic, Double
Pole, One Open Curcuit, One Closed Curcuit, Key Reset
Fire 93.86
279B-1110 Pull Station, Noncoded, Double Action, Break Glass, Plastic, Single
Pole, Open Curcuit, Wire Leads, Tool Reset
Fire 52.26
280A-PL Heat Detector Accessory, Reversable Plastic Mounting Plate, White Fire 4.66
281B-PL Heat Detector, 135°F Fixed/Rate of Rise, White Fire 15.34
282B-PL Heat Detector, 194°F Fixed/Rate of Rise, White Fire 15.34
283B-PL Heat Detector, 135°F Fixed, White Fire 15.34
284B-PL Heat Detector, 194°F Fixed, White Fire 15.34
320A Photoelectric Smoke Alarm, 120VAC Smoke Alarm w/Sounder Fire 68.46
320ACC Photoelectric Smoke Alarm w/Relay, Form A and C Relays That Do Not
Operate From the Tandem Circuit; They Must Detect Smoke
Fire 82.48
320ACX Photoelectric Smoke Alarm w/Tandem Relay, Form A and C Relays
That Do Operate From the Tandem Circuit and When Smoke Is
Detected
Fire 83.44
350 Photoelectric Smoke Alarm w/Battery Backup, 120VAC Smoke Alarm
w/Sounder and Backup Battery
Fire 72.52
350CC Photoelectric Smoke Alarm w/Relay and Battery Backup, Form A and C
Relays That Do Not Operate From the Tandem Circuit; They Must
Detect Smoke. Includes Backup Battery
Fire 92.26
350CX Photoelectric Smoke Alarm w/Tandem Relay and Battery Backup, Form
A and C Relays That Do Operate From the Tandem Circuit and When
Smoke Is Detected. Includes Backup Battery
Fire 92.72
405-01 Polarity Reversal Relay, 24VDC for Use w/2 or 4-Wire Smoke
Detectors. 1 Circuit. Enables Any Control Panel to Trip All ESL Sounder
Smoke Detectors On a Loop When Alarm is Detected. UL Listed.
CSFM
Fire 54.52
405-03 Polarity Reversal Relay, 12VDC for Use w/2 or 4-Wire Smoke
Detectors. 1 Circuit. Enables Any Control Panel to Trip All ESL Sounder
Smoke Detectors On a Loop When Alarm is Detected. UL Listed
Fire 53.56
405-05 Polarity Reversal Module, 12/24VDC, 4-Wire Smoke Detectors Only.
Enables Any Control Panel to Trip All ESL Sounder Smoke Detectors
On a Loop When Alarm is Detected. UL, MEA and CSFM Listed
Fire 52.32
405-06 DPDT Fire Auxiliary Relay, Allows Smoke Detectors to Initiate Two
Auxiliary Functions. 12/24VDC. UL, MEA and CSFM Listed
Fire 46.16
GE Security Intrusion Price List