Sharp ER-01PU Specifikace Strana 6

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 86
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 5
ER-OIPU
8.
IPL interface
1)Interface specifications
Asynchronous mode
1 STOP bit
Handshake
Poling (simplified procedure) fixed
Bit length
8 bits fixed
Parity check
Perfoned/Not performed (selected with
DIP SW)
Parity selection
Even number/Odd number/No (selected
with DIP SW)
Baud rate selection
2400/4800/9600/19200/38400 (selected
with DIP SW)
2) Handshake: Simplified procedure
Protocol:
HOST
I
PROGRAM DATA
8
t
t
t
I
,
,
[
PROGRAM DATA
q
EOT
PRINTER
ACK
ACK
ACK
1
,
,
8
t
t
I
,
,
I
1
,
,
ACK
When receiving program data, the printer checks the checksum. If no
error is found, the printer returns ACK. If any error is found, the
printer returns NAK.
If the host computer resends the data in spite of the printer returning
ACK, the printer ignores the data and returns ACK again.
(Whether to resend the data be not is judged based on the sequence
NO. in the program data packet.)
The time-out period is 10 seconds.
3) DATA FORMAT:
1. ENQ : 05h 2. ACK :
06h
3. NAK :
15h
4. EOT : 04h
5. PROGRAM DATA
A
A
4
i
PROGRAMDATA(binary)
(256bytes)
Checksum
SequenceNo.
I
Endcode(ODh)
Startcode(02h)
Sequence NO.
1 BYTES 30h---39h ring counter
Checksum
Lower 8-bit data of two’s complement of
sum of 1 BYTES PROGRAM DATA
PROGRAM DATA
Binary 256 BYTE fixed DATA
9. Dip switch
1) Table 1. Switch 1
Switch No.
Function
ON
OFF
1
Handshake
XON/XOFF TDR/DSR
,
i
2
Bit length
7 bits
8 bits
3
Paritycheck
Performed
Not performed
4 Parity selection
Even number
Odd number
I
I
—.
1
I Criteria for
I Receive I Receive
I
15
I BUSYcondition I BUFFER FULL I BUFFER FULL I
and OFF-LINE
6
m
Baud rate selection (See Table 2.)
I
t
8
I
2) Table 2. Baud Rate
Baud rate
Switch No.
[BPS]
“6
7 8
2400 ON OFF OFF
4800 OFF
ON ON
9600 OFF ON OFF
19200
OFF
OFF ON
t 38400
OFF OFF OFF
I
3) Table 3. Switch 2
Switch No. Function
ON
OFF
.
MODE IPL MODE x
Normal MODE
I
selection
2
in case of data Ignored
Prints “?”
reception errors
In case of data Connect
Not connect
3
reception
errors connect
to the host
4 Print density selection (See Table 4.)
5
6
7
Print speed (See Table 5.)
I
8
I
X For normal use,do not turn on the IPL mode.
1-5
Zobrazit stránku 5
1 2 3 4 5 6 7 8 9 10 11 ... 85 86

Komentáře k této Příručce

Žádné komentáře