Extron System 8/10 P
LUS
Users Manual
Multiple Switcher Operation
System 8/10 PLUS Switch Settings
From the front access panel on the System 8/10 PLUS, do the following:
1. On DIP switch block SW15, set switches #6 and #8 up”.
2. Set rotary switch RS4 to the “0” position (RS-232 mode).
On the rear panel of the System 8/10 PLUS, do the following:
3. Set the Norm/VLB switch on the back of the 8/10 PLUS to Norm”.
4. Set the Address switches for master. (If looping two 8/10 PLUS systems to the
System 4, the second one must be set as a slave.)
5. Set the Video/RGBS switches to match the type of video to be used by each
input and do the configuration setup.
Go to page 4-7 of the System 4 Users Manual to configure the master/slave as a system.
_____ Refer to the previous pages for other switch settings.
Looping with System 4