VISUAL OBSERVATIONS
*
Check thermocouple position in flame. Refer to
Figure 8. The Thermocouple should be seated
securely in its bracket with the sensing end ex-
tended over the flame, as shown. Lack of proper
Thermocouple position can cause flame blowout
symptoms or failure to hold the flame when try-
ing to ignite the burner.
*
Check thermocouple connection to the Inter-
rupter and the Interrupter connection to the Gas
control insuring connections are tight. The same
flame failures as stated above can result from
loose connections.
DO NOT OVER-TIGHTEN THE CONNECTIONS
ON EITHER SIDE OF THE INTERRUPTER. THE
CORRECT PROCEDURE FOR BOTH CONNEC-
TIONS IS TO TURN THE CONNECTOR UNTIL IT
IS FINGER TIGHT; THEN TIGHTEN IT A QUAR-
TER TURN MORE.
*
Check the orange wires from the Interrupter
switch to the Selector switch to insure good con-
nections from the Interrupter terminals to G3 & W3
on the Selector switch. Refer to Figures 9 and 10.
Figure 8 - Burner Assembly
CAUTION
Figure 10 - Orange Wire Connections
Figure 9 - View of Interrupter Switch
11