23-2
Computer Link
23
23-2 Data flow
Specify the CCD-TRIG (camera 1) or the PARALLEL (parallel interface) as the source of the MEAS
INP I/F (measurement start input) signal.
See Chapter 21 "Setting the Input/Output Conditions."
The data flow for a measurement start input (CCD trigger/parallel) signal and an object type change
command (parallel) is shown below.
IV-C35M
Measuring
1 Enter measurement start signal.
(CCD trigger/parallel)
3 Receive a completion response.
2 Write measurement data.
PC
2,3: Computer link
CCD camera or PC
The block of measurement data to be written from the IV-C35M to the PC, in step , can be
specified on the "OBJ-TYPE I/O" screen.
See page 21-25.
When a Sharp PC is connected
The IV-C35M sends write enable command (EWR) to the PC in the following cases.
- When the power is applied to the IV-C35M.
- When a Sharp PC is selected.
- When a write mode nonconformity error (code 10(H)) occurs after a result write command (WRG) is
transmitted (when the power is disconnected from the PC).
When a Mitsubishi, OMRON, or Yokogawa PC is connected
The data in items and are divided into packets for transmission.
Zobrazit stránku 337
1 2 ... 333 334 335 336 337 338 339 340 341 342 343 ... 382 383

Komentáře k této Příručce

Žádné komentáře

Massive Iluminación exterior manuales de usuario

Empezando en L

Haga clic en el alfabeto a continuación para desplazarse a la lista completa de modelos que comienzan con esa letra

Modelos Tipo de documento
Lecce
Manual   Massive Wall light 16275/30/10, 2 paginas