Sharp IV-08MP Uživatelská příručka

Procházejte online nebo si stáhněte Uživatelská příručka pro Televizory a monitory Sharp IV-08MP. Sharp IV-08MP User`s guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 235
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - User’s Guide

MP-70 and MP-50Scoreboard ControllerUser’s GuideDocument No. 98-0002-29Revision Date: 10-27-06Effective with firmware ver. 2.15 and up.

Strany 2 - RF Exposure

MP-70/50 Scoreboard Controller User’s GuidexViewing your settings ... 126Changing your settings ...

Strany 3

MP-70/50 Scoreboard Controller User’s Guide88

Strany 4

8910If track is not the sport currently selected on the MP-70/50, see “SELECTING AND CHANGING SPORTS” ON PAGE 173.You should also verify that the cont

Strany 5

MP-70/50 Scoreboard Controller User’s Guide90Minutes tens to connector 2This setting is exclusive to the to the FB-8218TK scoreboard, which sup-port f

Strany 6

Chapter 10: Track91FinishLynxFinishLynx is a versitile digital photofinish and track timing system that can be connected to an MP-70 control, and is a

Strany 7

MP-70/50 Scoreboard Controller User’s Guide92You should also be familiar with the information in “COMMON FUNCTIONS” ON PAGE 13, which discusses severa

Strany 8

Chapter 10: Track93Entering lane and place informationFollow these steps to enter lane and place information for up to eight con-testants:1. Press DOW

Strany 9

MP-70/50 Scoreboard Controller User’s Guide94FinishLynx installation and setupIf you have selected the FinishLynx option, as explained in “FINISHLYNX”

Strany 10

Chapter 10: Track95FinishLynx SetupOpen the FinishLynx software on your PC, and set up FinishLynx by using the following procedure.1. The Options box

Strany 11 - Table of Contents

MP-70/50 Scoreboard Controller User’s Guide96•In the Name box, choose the name of your scoreboard configuration.•In the Code Set box, choose Single By

Strany 12

9711If baseball is not the sport currently selected on the MP-70/50, or if you want to change the controller’s settings for baseball, see “SELECTING A

Strany 13 - Introduction

Table of ContentsxiWireless system settings ... 158Exiting system settings ...

Strany 14 - Wireless and battery features

MP-70/50 Scoreboard Controller User’s Guide98Sport-specific settings for baseballWhen you select baseball, the MP-70/50 offers the sport-specific sett

Strany 15 - Wireless option

Chapter 11: Baseball99Countdown clockPress YES if you want the clock to count down or NO if you want the clock to count up.Tenths of seconds clockIf y

Strany 16 - About this user guide

MP-70/50 Scoreboard Controller User’s Guide100Auto hornIf you press YES to select auto horn, this mode is active each time you select baseball as the

Strany 17 - Chapter l: Introduction

Chapter 11: Baseball101Operating the control in a baseball gameBefore continuing with this chapter, be sure the letters BA appear in the upper-left co

Strany 18 - Getting help

MP-70/50 Scoreboard Controller User’s Guide102Tracking the score by inningIf the MP-70/50 is programmed for use with the BA-7127 or BA-7136 (scoreboar

Strany 19 - Necessary information

Chapter 11: Baseball103Balls, strikes, and outsThe 1 PRESS BSO feature (see “SINGLE-PRESS BALLS, STRIKES, OUTS” ON PAGE 98) allows you to increase the

Strany 20 - Important Precautions

MP-70/50 Scoreboard Controller User’s Guide104Updating hitsPress HIT to turn the hit indicator on and off.If your scoreboard type allows you to tally

Strany 21 - Hardware

Chapter 11: Baseball105Tracking errorsPress ENTER to turn the error indicator on or off. With some scoreboard types, the prompt at left appears when y

Strany 22

MP-70/50 Scoreboard Controller User’s Guide106

Strany 23 - VIEWS” ON PAGE 10

10712Lacrosse is a selection only for scoreboard type 21. Hence, your scoreboard must be set for scoreboard type 21 in order for you to see the prompt

Strany 24 - Turning on the MP-70/50

MP-70/50 Scoreboard Controller User’s Guidexii

Strany 25 - Functions

MP-70/50 Scoreboard Controller User’s Guide108• You may skip a prompt by pressing the NEXT key. This will advance you to the next prompt, but will sav

Strany 26 - Clock set key

Chapter 12: Lacrosse109Jumping clockThis setting is helpful when your scoreboard does not have a fifth digit for tenths of seconds. If you choose this

Strany 27 - “SELECTING AND CHANG

MP-70/50 Scoreboard Controller User’s Guide110Break set toOn the numeric keypad, enter the duration of the break period (half time) in minutes and the

Strany 28 - Updating the Score

Chapter 12: Lacrosse111Operating the control in a lacrosse gameBefore continuing with this chapter, be sure the letters LC appear in the upper-left co

Strany 29 - Sounding the horn

MP-70/50 Scoreboard Controller User’s Guide112In Lacrosse, there are three penalty clocks per team, and the MP-70/50 can store up to five penalties pe

Strany 30 - (MP-70 only)

Chapter 12: Lacrosse113Edit or clear penalties1. Press HOME PENALTY or VISITOR PENALTY.2. Press the CLR key to clear the penalty.3. The control prompt

Strany 31 - Tracking timeouts

MP-70/50 Scoreboard Controller User’s Guide114

Strany 32 - Using the shifted functions

11513About the Pace ClockThe Pace Clock is a unit that hangs on a wall, which runners can use to pace laps around a track. The Pace Clock can be opera

Strany 33 - SHIFT+T.O.D. and respond

MP-70/50 Scoreboard Controller User’s Guide1163. Respond YES to the prompt shown below to exit SYSTEM SETTINGS.Change Sport to Football4. Next, you wi

Strany 34 - YES and NO

Chapter 13: Pace Clock117Countdown clock Respond NO at this prompt. Auto hornRespond NO at this prompt.Timeout to scoreboardRespond NO at this prompt.

Strany 35 - 1ST & 10

11About the MP-70 and the MP-50This manual describes the use of two Trans-Lux/Fair-Play products, the MP-70 control, and the MP-50 control. Both produ

Strany 36 - Dimming the scoreboard

MP-70/50 Scoreboard Controller User’s Guide118Break set toPress 00, then press ENTER.Overtime set toPress 00, then press ENTER.Timeout timer set toPre

Strany 37 - Basketball

11914Team name displays (MP-70 only)If your scoreboard is equipped with SpectraLens or LED technology elec-tronic team names displays, the MP-70 contr

Strany 38

MP-70/50 Scoreboard Controller User’s Guide120To scroll through the letters more easily, press and hold either key, After about a second the cursor wi

Strany 39 - Enter lineup (MP-70 only)

Chapter 14: Team Names1213. To select the first letter of the team name, use the 4/YES or 6/NO keys to position the cursor under the required letter.

Strany 40 - Maximum team fouls

MP-70/50 Scoreboard Controller User’s Guide1227. Though the control allows entry of up to 11 characters per team name, a 32-pixel width team name wind

Strany 41

12315The wireless option available with the MP-70/50 allows you to control most indoor scoreboards and shot clocks, or most outdoor scoreboards and fi

Strany 42 - Time set to (MP-70 only)

MP-70/50 Scoreboard Controller User’s Guide124Setting up the wireless connectionThe wireless MP-70/50 and receiving devices must be located within ran

Strany 43 - Second timeout time

Chapter 15: Wireless125The wireless signal is largely immune to conflicting radio frequency signals from cordless telephones, cellular telephones, mic

Strany 44

MP-70/50 Scoreboard Controller User’s Guide126High and low power modesThe wireless data link can operate in either• HIGH POWER mode - In HIGH POWER m

Strany 45 - FIBA rules explained

Chapter 15: Wireless127Changing your settingsHigh power transmitTo change any or all of these three settings, hold down the SHIFT key and press the nu

Strany 46 - QUESTION)” ON PAGE 26)

MP-70/50 Scoreboard Controller User’s Guide2The MP-70The MP-70 is the most popular Trans-Lux/Fair-Play scoreboard controller. It can operate all stand

Strany 47

MP-70/50 Scoreboard Controller User’s Guide128Selecting channelsIn SEL mode, you must select the same channel on both the MP-70/50 and its receiving d

Strany 48 - Controlling the bonus lights

Chapter 15: Wireless129Receiver card locationThe receiver card is located in either the processor mounting area or the radio frequency data converter

Strany 49 - “NEW GAME” ON

MP-70/50 Scoreboard Controller User’s Guide130Locating channel switch on receiver cardIf you are having trouble locating the channel switch on the sco

Strany 50

Chapter 15: Wireless131On high-voltage outdoor displays (and Telelite conversions), the channel switch is located behind a hole in the side of the rec

Strany 51 - Chapter 4: Basketball

MP-70/50 Scoreboard Controller User’s Guide132Turning wireless offYou will need to turn off the wireless feature if you want to hook up a wire-less-eq

Strany 52 - CLR key

Chapter 15: Wireless1335. At the last prompt, the settings that you have selected will display on the LCD screen. In the example below, the user has s

Strany 53 - 70 only)

MP-70/50 Scoreboard Controller User’s Guide134General wireless operating guidelines• Maintain a clear, unobstructed line-of-sight between the control

Strany 54 - Tracking fouls (MP-70 only)

Chapter 15: Wireless135• Before establishing communication between a control set to ALL SCBDS and its intended receiving scoreboards, be sure to have

Strany 55

MP-70/50 Scoreboard Controller User’s Guide136Operating wireless under special circumstancesThe following sections will give you pointers on setting u

Strany 56

Chapter 15: Wireless137Mixing wireless and conventional cable hookupsTo use conventional control wire with a scoreboard, first disconnect the wireles

Strany 57 - Football

Chapter l: Introduction3Wireless optionControls with the wireless option are versatile and secure, without the need for wiring and cable conduit that

Strany 58 - Update yardage

MP-70/50 Scoreboard Controller User’s Guide138Power-up sequence for multiple controlsFor systems using multiple wireless MP-70/50s, observe the follow

Strany 59

Chapter 15: Wireless139In a volleyball tournament, for example, you could display the scores of two matches on two independent scoreboards, each contr

Strany 60 - Timer set to (MP-70 only)

MP-70/50 Scoreboard Controller User’s Guide140ALL, the MP-70/50 controls all scoreboards within range, regardless of which select channel they are usi

Strany 61

Chapter 15: Wireless141Avoiding potential problems with multiple controlsIn facilities where one or more scoreboards are already synchronized to the s

Strany 62

MP-70/50 Scoreboard Controller User’s Guide142The reason for these garbled signals is that the wireless specification doesn’t allow the simultaneous u

Strany 63 - Chapter 5: Football

Chapter 15: Wireless143• An alternative method would be to set the two scoreboards and one control of court 1 all to the same channel and transmit wir

Strany 64

MP-70/50 Scoreboard Controller User’s Guide144Operating the MP-70/50 in Relay ModeRELAY mode enables an MP-70/50 to retransmit the scoreboard control

Strany 65

Chapter 15: Wireless145RELAY mode is used instead of changing the channel when synchroniza-tion is required. Take the following steps to accomplish th

Strany 66 - Interval timer on

MP-70/50 Scoreboard Controller User’s Guide146Wireless TroubleshootingThe following section suggests possible solutions to problems you may encounter,

Strany 67 - 10’ Penalty Spots

Chapter 15: Wireless147Cell filter kitsIf you encounter a situation where your wireless scoreboard lights start flickering for no apparent reason, or

Strany 68

MP-70/50 Scoreboard Controller User’s Guide4About this user guideThis User Guide will acquaint you with the MP-70 and MP-50 Scoreboard Controls. It in

Strany 69

MP-70/50 Scoreboard Controller User’s Guide1485. Make sure the control is programmed for high power radio transmis-sion, as instructed at “HIGH AND LO

Strany 70

14916Under normal circumstances, you should not have to change the System Settings configuration of your MP-70/50, as this is normally done at the Fai

Strany 71

MP-70/50 Scoreboard Controller User’s Guide150Programming SequenceInitial control programming needs to be performed in the following sequence:1. SYSTE

Strany 72 - Entering penalties

Chapter 16: System Settings151System settings in detailThe first prompt you will receive is SCBD TYPE.Scoreboard typeThe MP-70/50 must be properly con

Strany 73 - ENTER after each

MP-70/50 Scoreboard Controller User’s Guide152System settings for BaseballThe following two-page section describes features found on Baseball scoreboa

Strany 74 - Entering multiple penalties

Chapter 16: System Settings153Settings for baseball board type 33If board type 33 has been entered, the prompts shown below appears next in the sequen

Strany 75 - Chapter 6: Hockey

MP-70/50 Scoreboard Controller User’s Guide154Pitch speed (board types 34 & 39)Pitch speed is available only for scoreboard types 34 and 39. To di

Strany 76

Chapter 16: System Settings155MP-70 and MP-69 data outputsYour Fair-Play scoreboard requires data in one of two formats: MP-70 or MP-69.• MP-69 is a d

Strany 77

MP-70/50 Scoreboard Controller User’s Guide156The MP-70/50 can provide data in either format. The prompts shown above allow you to specify which data

Strany 78 - SHIFT key at the same time

Chapter 16: System Settings157If CONNS 1 & 2 are both set to MP-69 data, you will not be given the TEAM NAME prompt. Otherwise the TEAM NAME promp

Strany 79 - Using the interval timer

Chapter l: Introduction5Conventions used in this guideThe following conventions are used throughout this manual to help you identify actions, terms, h

Strany 80

MP-70/50 Scoreboard Controller User’s Guide158Wireless system settingsThe following three prompts will only appear if your control has the wire-less o

Strany 81 - Wrestling

Chapter 16: System Settings159Boards supportedBoards SupportedBoard type numberMP-50 Compatible BoardsBoard Using MP-69 DataBoards Using MP-70 Data00

Strany 82

MP-70/50 Scoreboard Controller User’s Guide16004 BB-6730 BB-1720, BB-1722, BB-1760, BB-177005 BB-6662,BB-6760,BB-6770BB-1635, BB-1735, BB-1855, BB-186

Strany 83

Chapter 16: System Settings16112 BB-1726, BB-1766, BB-177613 HK-6704,HK-6704-4,HK-6704-45,HK-6705,HK-6705 SN,HK-6705-45,HK-6714HK-1650, HK-1655, HK-17

Strany 84

MP-70/50 Scoreboard Controller User’s Guide16223 FB-8120 series, FB-8127 series, FB-8132 series,SC-8120, MP-8114CL-1031, FB-8120 series,FB-8127 serie

Strany 85

Chapter 16: System Settings16333 BA-7118 BA-7118,BA-7118MP34 BA-7127 series,BA-7128,BA-7136, BA-7136 TODBA-7126 series, BA-7127 series, BA-7128,BA-713

Strany 86 - HOME or VISITOR SCORE

MP-70/50 Scoreboard Controller User’s Guide164

Strany 87

16517The battery option, available on both standard and wireless MP-70/50 controls, provides an on-board power source that virtually eliminates the ne

Strany 88 - “PROGRAMMING THE SYSTEM SET

MP-70/50 Scoreboard Controller User’s Guide166The electronic function of battery powered MP-70 is exactly the same as its AC-powered cousin with only

Strany 89 - Sum Clock Time

Chapter 17: Battery Option167If the battery pack discharges to a very low level, the control will issue an audio-visual warning. The beeper will “chir

Strany 90

MP-70/50 Scoreboard Controller User’s Guide6Getting helpIf you experience trouble with your Trans-Lux/Fair-Play equipment and controller after reviewi

Strany 91

MP-70/50 Scoreboard Controller User’s Guide168• NiMH batteries tend to perform better and last longer if allowed to completely recharge to the “BATTER

Strany 92

Chapter 17: Battery Option169• When the battery charger is not in use, unplug it from the AC wall power outlet.If the control is operated in mild temp

Strany 93 - Displaying shots on goal

MP-70/50 Scoreboard Controller User’s Guide170It is normal for battery controls to self-discharge over time, even when they are switched off. The rate

Strany 94

Chapter 17: Battery Option171• Never dispose of the battery pack in fire. Also disposing of NiMH bat-teries in household or business trash containers

Strany 95 - Volleyball

MP-70/50 Scoreboard Controller User’s Guide172

Strany 96

17318Under normal circumstances, you should not have to change the sport configuration of your MP-70/50, as the control has a memory circuit that reta

Strany 97

MP-70/50 Scoreboard Controller User’s Guide174Sport CodesFollowing the start up message, a two-letter code representing the sport currently selected a

Strany 98

Chapter 18: Change Sport1751. Turn off the MP-70/502. Press and hold the ENTER key while turning on the MP-70/50. The following messages appear on the

Strany 99 - Displaying the game number

MP-70/50 Scoreboard Controller User’s Guide176Basketball (cont.)PAGE 27POINTS MEMORY? If you have selected the FOUL MEMORY prompt, this tracks points

Strany 100

Chapter 18: Change Sport177Basketball (cont.)PAGE 29JUMPING CLK? If you have selected the 1/10th Sec Clk option listed above, this option moves digits

Strany 101 - NEXT key. This will advance

Chapter l: Introduction7Necessary information Before contacting Trans-Lux Fair-Play, please write down the information requested in the following spac

Strany 102 - Omega Powertime

MP-70/50 Scoreboard Controller User’s Guide178Basketball (cont.)PAGE 32#OFTOLS 1 TO 9? Sets total number of timeouts allowed.FootballPAGE 45UPDATE YAR

Strany 103 - Operating in Manual Mode

Chapter 18: Change Sport179Football (cont.)PAGE 48TIMER SET TO?FootballPAGE 48CLOCK SET TO? Sets total minutes of game period.FootballPAGE 49BREAK SET

Strany 104 - Displaying the event number

MP-70/50 Scoreboard Controller User’s Guide180Hockey (cont.)PAGE 56JUMPING CLK? If you have selected the 1/10th Sec Clk option listed above, this opti

Strany 105 - Displaying event results

Chapter 18: Change Sport181Wrestling (cont.)PAGE 69COUNT DN. CLK? Specifies whether the clock counts up or down.WrestlingPAGE 701/10 SEC CLK? Specifie

Strany 106 - FinishLynx Installation

MP-70/50 Scoreboard Controller User’s Guide182Wrestling (cont.)PAGE 72#OFTOLS 1 TO 9? Sets total number of timeouts allowed.SoccerPAGE 76MT TO CONN 2?

Strany 107 - Script box, choose Dak.lss

Chapter 18: Change Sport183Soccer (cont.)PAGE 78AUTO HORN? Programs the control to sound the horn for five seconds at the end of a period.SoccerPAGE 7

Strany 108

MP-70/50 Scoreboard Controller User’s Guide184Volleyball (cont.)PAGE 84JUMPING CLK? If you have selected the 1/10th Sec Clk option listed above, this

Strany 109 - Baseball

Chapter 18: Change Sport185Baseball (cont.)PAGE 971 PRESS BSO? Allows you to increase the ball, strike and out values with a press of the numeric key.

Strany 110 - Sport-specific settings for

MP-70/50 Scoreboard Controller User’s Guide186Lacrosse(cont.)PAGE 1081/10 SEC. CLK? Displays tenths of sec-onds in the last minute of play.LacrossePAG

Strany 111 - Jumping clock

Chapter 18: Change Sport1875. When you see the prompt below, press YES if you want to accept the new settings and exit PROGRAM MODE. Press NO to selec

Strany 112 - Auto horn

MP-70/50 Scoreboard Controller User’s GuideiiThis device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.Operation is subje

Strany 113 - Operating the control in a

MP-70/50 Scoreboard Controller User’s Guide8Important Precautions• Read this manual thoroughly before setting up or operating the MP-70/50.• Do not dr

Strany 114 - Tracking the score by inning

MP-70/50 Scoreboard Controller User’s Guide188Saving a configurationBefore returning to normal operation you will be asked to enter a name for the con

Strany 115 - Balls, strikes, and outs

Chapter 18: Change Sport189Changing keypad insertAfter selecting a different sport, you may also need to change the keypad insert. Follow these steps:

Strany 116 - Updating runs

MP-70/50 Scoreboard Controller User’s Guide190

Strany 117 - Tracking errors

19119If the problem you are experiencing fits a description below, try the solu-tions suggested. If you need additional help, see “CONTACTING THE HELP

Strany 118

MP-70/50 Scoreboard Controller User’s Guide192Scoreboard does not respondIf portions of the scoreboard do not respond, or the scoreboard otherwise doe

Strany 119 - (board type 21)

19320Purpose of the Segment TimerWhen you want to put your team through a practice drill you can use the Segment Timer feature to keep track of those

Strany 120

MP-70/50 Scoreboard Controller User’s Guide194Program Mode for Segment TimerTo program the Segment Timer, press down the SHIFT and 2 keys together whi

Strany 121 - Clock set to

Chapter 20: Segment Timer Operation195When you have entered your correct times for the Segment Timer, exit the Program Mode for Segment Timer by press

Strany 122 - Number of timeouts left

MP-70/50 Scoreboard Controller User’s Guide196Last, the LCD screen displays a question that asks, “Seg. (Segment) Timer Mode?” •Press YES to return t

Strany 123

Chapter 20: Segment Timer Operation197Running Segment ModeActivate the Segment TimerTo run the Segment Timer, press and hold down the 2 key and simult

Strany 124

92The figure below acquaints you with the control’s major components.(Wireless control is shown).Connect scoreboards, hand switches, and other devices

Strany 125 - Chapter 12: Lacrosse

MP-70/50 Scoreboard Controller User’s Guide198The segments and breaks either:• Increment (Inc.), meaning that they count up (example: 1,2,3,4); or, •

Strany 126

Chapter 20: Segment Timer Operation199BreaksBreaks have the same number as their corresponding segment.When you run the MP-70/50 in Break Mode, the up

Strany 127 - Programming the Pace Clock

MP-70/50 Scoreboard Controller User’s Guide200Designing segment training intervalsTrans-Lux Fair-Play recommends that the Segment Timer option of your

Strany 128 - Football programming sequence

Chapter 20: Segment Timer Operation201

Strany 129 - Chapter 13: Pace Clock

MP-70/50 Scoreboard Controller User’s Guide202

Strany 130 - Changing direction arrows

20321This chapter will help you operate the MP-70/50 control in a special TEST mode in order to verify that all lamp circuits are functioning properly

Strany 131

MP-70/50 Scoreboard Controller User’s Guide204At this point the fully illuminated board will hold for approximately three seconds. During that time th

Strany 132

20522This chapter will help you load configurations on your MP-70/50 control Loading a configuration programs all settings in both SYSTEM and SPORT le

Strany 133 - SHIFT key

MP-70/50 Scoreboard Controller User’s Guide2064. The bottom line will prompt you with the name of the first available configuration. Press YES to sele

Strany 134 - SETTINGS” ON PAGE 149

20723Please give us your input!In an effort to provide you with the most accurate, up-to-date information possible, Trans-Lux/Fair Play has provided t

Strany 135 - Wireless

MP-70/50 Scoreboard Controller User’s Guide10MP-70 and 50 - back panel views

Strany 136 - Setting up the wireless

MP-70/50 Scoreboard Controller User’s Guide208

Strany 137 - Selecting transmission modes

209About this guideThis is intended to be used as a portable document that you can use during sport-ing events to program your MP-70/50’s systems sett

Strany 138 - Viewing your settings

MP-70/50 Scoreboard Controller User’s Guide210ShortcutsChoosing/changing a sportPower on + ENTER.Programming system settingsPower on + 0Load configura

Strany 139 - Changing your settings

Chapter 23: Quick Reference Guide211

Strany 140 - Selecting channels

MP-70/50 Scoreboard Controller User’s Guide212Wireless segmentSetting Up Wireless:Locate the MP-70/50 wireless control in a place where it and the rec

Strany 142

MP-70/50 Scoreboard Controller User’s Guide214

Strany 143 - Chapter 15: Wireless

Index215IndexNote: Sport-specific settings in this index are listed under their specific sport(s).Numerics1st & 10 key 23Aactivating segment timer

Strany 144 - Turning wireless off

MP-70/50 Scoreboard Controller User’s Guide216out key 98outs 103pitch speed 154player at bat 103player number 103runsautomatic total 98updating 104sco

Strany 145

Index217time set 30timeout timer to 31timeout to scoreboard 30tracking fouls 42updating score 41visitor bonus key 36visitor fouls key 39, 42, 43, 44vi

Strany 146 - General wireless operating

Chapter 2: Hardware11Optional hand switches (MP-70 only) Fair-Play offers the following optional hand switches for use with the MP-70.When connecting

Strany 147 - “AVOIDING

MP-70/50 Scoreboard Controller User’s Guide218first and 10 key 23football 45–51auto horn 48, 117break set to 49, 118clock set to 48, 117countdown cloc

Strany 148 - Operating wireless under

Index219set interval on button 67shots on goaldisplaying 59sports-specific settings 53ten minute penalty spots 55tenths of seconds clock 56timeout tim

Strany 149

MP-70/50 Scoreboard Controller User’s Guide220mp-70 data 155MP-7114 97Nnew game key 22next key 22, 26, 45, 53, 69, 75, 83, 89, 97, 108no key 22OOmega

Strany 150

Index221set timer/t.o.d. key 37setup 9shipping and receiving 7shot timer 11FIBA rules 11, 33shot/field timer 18signal lockwirelessverifying signal loc

Strany 151 - MODE” ON PAGE 144

MP-70/50 Scoreboard Controller User’s Guide222system settingstime of day clock 157time of day key 20, 21time out mode 17timeoutstracking 19timer reset

Strany 152

Index223locating 130channelsverifying 131connection 124field timer 156general guidelines 134hand switches 123high power mode 126high power transmit 12

Strany 153

MP-70/50 Scoreboard Controller User’s Guide12Turning on the MP-70/50Before turning on the MP-70/50, verify that it is connected to a standard 120-volt

Strany 154

133Certain functions of the MP-70/50 are common to all sports. You should become familiar with these functions before proceeding to the chapters discu

Strany 155

MP-70/50 Scoreboard Controller User’s Guide14Clock set keyThe CLOCK SET key allows you to set the clock for game, break, and overtime periods. This ke

Strany 156 - “SYNCHRO

Chapter 3: Common Functions15The first two characters on the top line of the LCD display indicate which period type is currently selected (BK for brea

Strany 157

MP-70/50 Scoreboard Controller User’s Guide16Updating the ScoreFollow these steps to enter or update the score:1. Press HOME SCORE or VISITOR SCORE.2.

Strany 158 - Wireless Troubleshooting

Chapter 3: Common Functions17Tracking periodsFollow these steps to enter or update the period number:1. Press PERIOD.2. Press one of the following key

Strany 159 - Cell filter kits

Table of ContentsiiiTable of ContentsCHAPTER 1 INTRODUCTION... 1About the MP-70 and the MP-50 ...

Strany 160 - Final wireless control

MP-70/50 Scoreboard Controller User’s Guide18Operating the shot/field timer (MP-70 only)You must have an HS-70 hand switch to operate the shot/field t

Strany 161 - System Settings

Chapter 3: Common Functions19Tracking timeoutsIf your scoreboard lets you display the number of timeouts left, this sec-tion will help you do so. If y

Strany 162 - Adjusting System Settings

MP-70/50 Scoreboard Controller User’s Guide20Correcting a mistakeIf you make a mistake while entering a number on the numeric keypad, press CLR. Then

Strany 163 - System settings in detail

Chapter 3: Common Functions21To display the time of day, press SHIFT + T.O.D. and respond with YES to the prompt T.O.D. CLOCK? Y/N. The display will t

Strany 164 - System settings for Baseball

MP-70/50 Scoreboard Controller User’s Guide22New GameThe MP-70/50 retains the data from the last game it was used for in mem-ory. This is a precaution

Strany 165 - Chapter 16: System Settings

Chapter 3: Common Functions23ESCIf you enter system settings by mistake, press ESC to skip directly to the QUIT prompt. This prevent inadvertent chang

Strany 166

MP-70/50 Scoreboard Controller User’s Guide24Dimming the scoreboardOutdoor scoreboards are easier to read if they are bright in the daylight and dim a

Strany 167 - MP-70 and MP-69 data outputs

254If basketball is not the sport currently selected on the MP-70/50, or if you want to change the controller’s settings for basketball, see “SELECTIN

Strany 168

MP-70/50 Scoreboard Controller User’s Guide26• You may skip a prompt by pressing the NEXT key. This will advance you to the next prompt, but will save

Strany 169 - Time of day clock

Chapter 4: Basketball27Foul memoryThe foul memory feature allows you track fouls or fouls and points by player number. You can display these statistic

Strany 170 - Exiting system settings

MP-70/50 Scoreboard Controller User’s GuideivCLK. UP/DN ... 22BLANK...

Strany 171 - Boards supported

MP-70/50 Scoreboard Controller User’s Guide28Bonus foulsOn the numeric keypad, enter the number of team fouls (between one and nine) needed to initiat

Strany 172

Chapter 4: Basketball29Tenths of seconds clockIf you want the clock to display tenths of seconds in the last minute of play, press YES. This setting i

Strany 173

MP-70/50 Scoreboard Controller User’s Guide30Timeout to scoreboardIf you want the timeout timer to appear on the scoreboard, press YES. If you press N

Strany 174

Chapter 4: Basketball31Break set to On the numeric keypad, enter the duration of the break period (half time) in minutes and then press ENTER.Overtime

Strany 175

MP-70/50 Scoreboard Controller User’s Guide32Number of timeouts leftEnter the number of timeouts allowed, either per game or per half. When you press

Strany 176

Chapter 4: Basketball33FIBA rules explained(The following sections describe features of FIBA rules. They are only appli-cable if you chose FIBA rules

Strany 177 - Battery

MP-70/50 Scoreboard Controller User’s Guide34FIBA Auto Per. Advance sequenceIf you chose the AUTO PERIOD ADVANCE feature that is an option under FIBA

Strany 178 - SHIFT+BAT/RF

Chapter 4: Basketball35Operating the control in a basketball gameBefore continuing with this chapter, be sure the letters BB appear in the upper-left

Strany 179 - Using and recharging battery

MP-70/50 Scoreboard Controller User’s Guide36Controlling the possession lightsPress the NEXT. POSS. key to alternate between the home and visitor poss

Strany 180

Chapter 4: Basketball37Setting the timer (MP-70 only)You can program and store two different default shot timer clock dura-tions (reset times) in perm

Strany 181 - Battery storage

Table of ContentsvSetting the timer (MP-70 only)... 37Displaying player statistics (MP-70 only) ...

Strany 182 - Battery control safety and

MP-70/50 Scoreboard Controller User’s Guide38The bottom half of the LCD screen will confirm your selection by display-ing TIMER RESET= the shot timer

Strany 183 - Chapter 17: Battery Option

Chapter 4: Basketball39Displaying player statistics (MP-70 only) Follow these steps to place a player in the game and display that player’s statistics

Strany 184

MP-70/50 Scoreboard Controller User’s Guide40Mass player substitutionFollow these steps to remove all of the players from either team for a mass playe

Strany 185 - Selecting and

Chapter 4: Basketball41Updating score/tracking player points (MP-70 only)When you are using the points memory option (see “POINTS MEMORY (MP-70 ONLY)”

Strany 186 - Sport Codes

MP-70/50 Scoreboard Controller User’s Guide42Tracking fouls (MP-70 only) Follow these steps to update team and player fouls.1. Press HOME FOULS or VIS

Strany 187 - Chapter 18: Change Sport

Chapter 4: Basketball43Correcting player statistics (MP-70 only)If the points memory feature is active (see “POINTS MEMORY (MP-70 ONLY)” ON PAGE 27),

Strany 188

MP-70/50 Scoreboard Controller User’s Guide44In situations where you wish to display information for two players on the team fouls panel, use the abov

Strany 189

455If football is not the sport currently selected on the MP-70/50, or if you want to change the controller’s settings for football, see “SELECTING AN

Strany 190

MP-70/50 Scoreboard Controller User’s Guide46• You may exit the programming sequence at any time by pressing the ESC key. This will take you to the Qu

Strany 191

Chapter 5: Football47Countdown clock Press YES if you want the clock to count down or NO if you want the clock to count up.Tenths of seconds clockIf y

Strany 192

MP-70/50 Scoreboard Controller User’s GuideviClock set to ... 57Break set to ...

Strany 193

MP-70/50 Scoreboard Controller User’s Guide48Auto hornIf you press YES to select auto horn, this mode is active each time you select football as the s

Strany 194

Chapter 5: Football49Break set toOn the numeric keypad, enter the duration of the break period (half time) in minutes and then press ENTER.Overtime se

Strany 195

MP-70/50 Scoreboard Controller User’s Guide50Operating the control in a football gameBefore continuing with this chapter, be sure the letters FB appea

Strany 196

Chapter 5: Football512. Press one of the following keys to adjust the yardage by the increment indicated: +1, +2, +3, or -1.Or1. Press TO GO.2. On the

Strany 197

MP-70/50 Scoreboard Controller User’s Guide52

Strany 198

536If hockey is not the sport currently selected on the MP-70/50 or if you want to change the controller’s settings for hockey, see “SELECTING AND CHA

Strany 199

MP-70/50 Scoreboard Controller User’s Guide54• You may exit the programming sequence at any time by pressing the ESC key. This will take you to the Qu

Strany 200 - Saving a configuration

Chapter 6: Hockey5510’ Penalty SpotsIf you choose YES for this option, then players who receive a 10-minute penalty will automatically have those pena

Strany 201 - Changing keypad insert

MP-70/50 Scoreboard Controller User’s Guide56Tenths of seconds clockIf you want the clock to display tenths of seconds in the last minute of play, pre

Strany 202

Chapter 6: Hockey57Timeout to scoreboardIf you want the timeout timer to appear on the scoreboard, press YES. If you press NO, the timer appears only

Strany 203 - Troubleshooting

Table of ContentsviiCountdown clock... 77Sum Clock Time...

Strany 204 - Scoreboard does not respond

MP-70/50 Scoreboard Controller User’s Guide58Overtime set to On the numeric keypad, enter the duration of the overtime period in min-utes and then pre

Strany 205 - Operation

Chapter 6: Hockey59Operating the control in a hockey gameBefore continuing with this chapter, be sure the letters HK appear in the upper-left corner o

Strany 206 - Program Mode for Segment

MP-70/50 Scoreboard Controller User’s Guide60Entering penaltiesBy default, the MP-70/50 allows you enter penalty times in two-minute five-minute, and

Strany 207

Chapter 6: Hockey61When you enter a penalty, the penalty indication arrow for the appropri-ate time lights for 12 seconds. There are two penalty clock

Strany 208

MP-70/50 Scoreboard Controller User’s Guide62Entering multiple penaltiesIf a player receives more than one penalty time, such as two 2-minute penaltie

Strany 209 - Running Segment Mode

Chapter 6: Hockey63Entering two penalties with plus keys1. Press the HOME PENALTY or VISITOR PENALTY keys.2. Press +1, +2 or +3 keys to assign a penal

Strany 210

MP-70/50 Scoreboard Controller User’s Guide64Entering Other penalties1. Press HOME PENALTY or VISITOR PENALTY.2. Press the OTHER key, which is located

Strany 211 - Exiting Segment Timer

Chapter 6: Hockey655. The player’s number, and that player’s current penalty in memory appears on the LCD display, as shown below. In this instance, t

Strany 212 - Designing segment training

MP-70/50 Scoreboard Controller User’s Guide66Tracking penaltiesTo view, or track existing team penalties, hold down the SHIFT key and hit the HOME PEN

Strany 213

Chapter 6: Hockey67Using the interval timerWhile the interval timer settings are usually adjusted in PROGRAM mode, you can also start, stop or change

Strany 214

MP-70/50 Scoreboard Controller User’s GuideviiiMinutes tens to connector 2... 90Omega Powertime ...

Strany 215 - Test Mode

MP-70/50 Scoreboard Controller User’s Guide68

Strany 216 - Team name testing

697If wrestling is not the sport currently selected on the MP-70/50, or if you want to change the controller’s settings for wrestling, see “SELECTING

Strany 217 - Configuration

MP-70/50 Scoreboard Controller User’s Guide70• You may exit the programming sequence at any time by pressing the ESC key. This will take you to the Qu

Strany 218

Chapter 7: Wrestling71Auto hornIf you press YES to select auto horn, this mode is active each time you select wrestling as the sport. You can still us

Strany 219 - Documentation

MP-70/50 Scoreboard Controller User’s Guide72Overtime set to On the numeric keypad, enter the duration of the overtime period in min-utes and then pr

Strany 220

Chapter 7: Wrestling73Operating the control in a wrestling matchBefore continuing with this chapter, be sure the letters WR appear in the upper-left c

Strany 221 - Reference

MP-70/50 Scoreboard Controller User’s Guide74Displaying previous match scoresUp to ten previous match scores can be displayed on scoreboards that have

Strany 222 - Shortcuts

758If soccer is not the sport currently selected on the MP-70/50, or if you want to change the controller’s settings for soccer, see “SELECTING AND CH

Strany 223

MP-70/50 Scoreboard Controller User’s Guide76• You may exit the programming sequence at any time by pressing the ESC key. This will take you to the Qu

Strany 224 - Wireless segment

Chapter 8: Soccer77Countdown clockPress YES if you want the clock to count down or NO if you want the clock to count up.Sum Clock TimeIf you chose NO

Strany 225 - Warranty

Table of ContentsixAuto horn ... 109Timeout to scoreboard...

Strany 226

MP-70/50 Scoreboard Controller User’s Guide78Tenths of seconds clockIf you responded YES to COUNT DN CLOCK?, the next prompt to appear will be the 1/1

Strany 227 - Numerics

Chapter 8: Soccer79Timeout to scoreboardIf you want the timeout timer to appear on the scoreboard, press YES. If you press NO, the timer appears only

Strany 228

MP-70/50 Scoreboard Controller User’s Guide80Timeout timer set to On the numeric keypad, enter the number of seconds per timeout and then press ENTER

Strany 229

Chapter 8: Soccer81Corner kicksThe CORNER KICKS key works much like the SCORE key. Follow these steps to use them.1. Press CORNER KICKS.2. Press one o

Strany 230

MP-70/50 Scoreboard Controller User’s Guide82Tracking penalties in a soccer gameIn a soccer game, the penalty keys also work much like the SCORE keys.

Strany 231

839If volleyball is not the sport currently selected on the MP-70/50, or if you want to change the controller’s settings for volleyball, “SELECTING AN

Strany 232

MP-70/50 Scoreboard Controller User’s Guide84• You may exit the programming sequence at any time by pressing the ESC key. This will take you to the Qu

Strany 233

Chapter 9: Volleyball85Auto hornIf you press YES to select auto horn, this mode is active each time you select soccer as the sport. You can still use

Strany 234

MP-70/50 Scoreboard Controller User’s Guide86Overtime set toOn the numeric keypad, enter the duration of the overtime period in min-utes and then pres

Strany 235

Chapter 9: Volleyball87You should also be familiar with the information in the chapter titled “COMMON FUNCTIONS” ON PAGE 13) , which discusses several

Komentáře k této Příručce

Žádné komentáře